Calculator · Fluid Mechanics

Pump Head & Power Calculator

A pump adds head to the fluid, and the power that takes follows from the flow rate it does so at. Power delivered to the fluid and power the driver must supply are two different numbers, and they are never merged here.

Inputs

Must satisfy 0 < η ≤ 100 %. Without it, only the power delivered to the fluid can be reported.

Results

Hydraulic power P = ρ g Q h_p

2.942 kW

The driver must supply 3.92266 kW at the stated efficiency.

Fluid density ρ1000 kg/m³
Volumetric flow rate Q0.02 m³/s
Pump head h_p15 m
Hydraulic power P_hyd2.942 kW
Shaft power P_in = P_hyd/η3.92266 kW
Efficiency η75 %

Assumptions

  • · Steady, incompressible flow through the pump.
  • · Hydraulic power is delivered to the fluid; shaft power is what the driver must supply.
  • · No pump curve, operating point, NPSH or motor selection is modelled.

Explore in the Lab

Put this pump on a flow path in the Bernoulli & Energy Lab

The pump head appears as the step up in the energy grade line.

Technical reference

P_hyd = ρ g Q h_p

P_in = P_hyd / η

P_hyd
hydraulic power delivered to the fluid[W]
P_in
shaft power the driver must supply[W]
Q
volumetric flow rate through the pump[m³/s]
h_p
head the pump adds to the fluid[m]
η
pump efficiency, 0 < η ≤ 1[-]
g
gravity, 9.80665 m/s²[m/s²]

Hydraulic power is what reaches the fluid; shaft power is what the driver delivers. Quoting one as the other is the most common error in pump sizing.

The head here is the head the pump actually adds. Working out the head a system demands is an energy-equation question, and a pipe system's losses belong to pipe flow.

No pump curve, operating point, NPSH, cavitation margin or motor selection is modelled. This is duty arithmetic, not pump selection.