Calculator · Fluid Mechanics

Venturi Meter Calculator

A Venturi infers a discharge from the pressure it takes to accelerate the flow into a throat. Continuity and the energy equation between the two sections give one relation, read forwards to get the flow from the differential and backwards to get the differential a flow produces.

Inputs

An inclined meter is a normal case; the elevations enter the relation directly.

Prescribed from calibration. It must be positive; no universal upper bound is imposed.

Results

Discharge Q = Cd A2 V2,ideal

0.012569 m³/s

The measured differential, read through this meter's own geometry.

Upstream area A10.007854 m²
Throat area A20.0019635 m²
Area ratio A2/A10.25
Differential p1 − p220 kPa
Ideal discharge (before Cd)0.012825 m³/s
Discharge coefficient Cd0.98
Throat velocity V26.532 m/s
Upstream velocity V11.633 m/s
Elevation difference z1 − z20 m
Fluid density ρ1000 kg/m³

Assumptions

  • · Steady, incompressible flow between two sections of one stream tube.
  • · Losses between the sections are represented solely by the discharge coefficient.

Explore in the Lab

Compare this meter with a Pitot and an orifice in the Flow Measurement Lab

The Lab keeps each principle's own assumptions visible.

Technical reference

A1 V1 = A2 V2

V2 = sqrt( 2[(p1−p2)/ρ + g(z1−z2)] / (1 − (A2/A1)²) )

Q = Cd A2 V2,ideal

A1, A2
upstream and throat areas[m²]
p1 − p2
measured differential pressure[Pa]
Cd
prescribed discharge coefficient, Cd > 0[-]
z1 − z2
elevation difference between the sections[m]

A differential that would make the bracket negative is not a small number: it is a state this meter cannot produce, and no flow is reported for it.

Equal upstream and throat areas give no usable differential, and the calculator says so rather than dividing by zero.

The discharge coefficient is a calibration input. This calculator never predicts one.